A lot of engineering is pattern recognition. (I suspect this is true of most professions, but am not in a position to say.) You can carefully examine every line on a drawing and every single bolt on site to figure out what’s going on, or you can count on pattern recognition and say “Hey, I’ve seen this before.” The latter path requires confirming whatever you short-cut your way to, but even so it’s faster and, frankly, less boring. Sometimes you run into something that pattern recognition says is wrong, even grotesque, but it’s actually fine. Two views of a beam end: The big (21 inches deep) beam supporting the wood joists is not only not connected to the beam running past its end (the one with terra cotta block covering its web) but it has no bolt or rivet holes for a connection. A beam end floating in mid-air is disconcerting, to say the least. The explanation is simple, in one sense: the big beam is cantilevered past a column off to the left. The beam that looks like it should be…